Zone
Single-Zone
Type
Non-Locating
Sensor Type
Cable
Max Sensor length
305 meters
Integration
Relay
Alarm
Visual + Audio
Versatility is key with the LD1000 liquid leak detector, as it is compatible with various cables and spot sensors, allowing for seamless integration into different setups. You have the flexibility to configure the detection response time to either 10 seconds or 2 minutes, depending on your specific needs.
This device is perfectly suited for tight spaces. It measures just 105mm wide, 140mm high, and 58mm deep and weighs just 765g. Equipped with an audible alarm and three LED lights, it ensures clear and immediate alerts whenever a leak is detected.
This liquid leak detection system can effortlessly connect to existing monitoring systems to streamline your overall monitoring process.
The unit is provided with relays and an RS485 port to integrate it with BMS. Whether you're dealing with exposed environments or simply need quick and reliable leak detection, this controller is your go-to solution.
Trust in the LD1000 water leak detection system to keep your spaces secure with its reliable performance, efficient design, and easy-to-notice alerts. Experience peace of mind knowing that your leakage detection needs are met with the utmost precision and effectiveness.
It is important to know the details of the LD1000 Liquid Leak Detector. This helps in finding out how good this device is.
Extensive Monitoring
This liquid leak detection system can monitor up to 1,000 feet with a sensing cable. It supports a combination of wire leak sensors and spot detectors together.
Modbus Connectivity
Complete connection with Building Management Systems for full productivity and control through RS485 and addressing through DIP switch.
Customizable Audible Alerts
Users can easily select the audible alarm annunciation that fits with their choice. By placing or removing the jumper on two prongs of the JMP2 pin on the control board.
Leakage Sensitivity
The sensitivity of the water leakage detection panel indicates how much water should be touched to the sensor to signal alarm conditions. Using R25, users can choose low, medium, and high sensitivity.
Detection Response Time
Users can set detection response time in the ranges from 10 seconds to 2 minutes when this liquid leakage detector is used with conductive fluid or chemical sensing cables.
Configurable Relays
Using DIP Switch (SW2) user can configure relay output to supervised or non-supervised, Latching or non-latching, alarm delay (10 sec to 2 min), & Summary alarm or separate leak & fault alarm.
LED Indications
This liquid detection system provides LED for the status of Power (Green for ok), Fault (Yellow for cable break), & leak (Red for water leak detection)
Quite/Test/Reset Button
Audio alarms initiated due to a leak or fault can be silenced with this button. Also, users can reset the system (by pressing two seconds) or self-test the system (by pressing continuously).
Form C Relays
Features 2 Form C output relays, one for leak alarms and the other for fault alarms, providing versatile alarm management capabilities like supervised or non-supervised.
Certifications
CE-certified and ETL-listed for quality assurance, meeting rigorous standards for reliability and performance. This Water leakage detection system is made in the USA.
Temp/Humidity Resilience
The system functions effectively even in extreme humidity conditions ranging from 5% to 95% RH, non-condensing, and within temperatures ranging from 0°C to 50 °C.
Space-Efficient Design
This water leak alarm panel is designed with a compact size with rich features. The system consists of a wall-mounted enclosure for convenient installation.
The absence of an efficient water leak detection system in a critical facility can lead to many risks including operational, financial, and human life. Let’s understand the impact of liquid leak detection.
Slow Detection
Problems in monitoring can cause leaks, resulting in more damage to structures and high safety problems.
Increased Damage
Bad leak detection increases the impact of damage caused by leaks. This leads to high-price repairs and danger to the environment.
Safety Issues
Hidden leaks cause safety dangers to people and property such as slipping, electrical problems, and structural damage that keeps lives and resources in danger.
Operational Disruption
Leaks can disrupt normal operations, causing downtime, production delays, and financial losses for businesses, particularly in critical industries like manufacturing and data centers.
Environmental Issue
Hidden water leakage can result in a dirty environment that impacts ecosystems, water animals, and soil quality. This leads to long-term damage.
Resource Wastage
Water leaks cause wastage of resources such as water, energy, and materials impacting conservation efforts and increasing operations prices for businesses.
Reputation Damage
Events related to leaks can impact a company's reputation, leading to the loss of customers and investors and legal action.
Compliance Issues
Failure to find and repair leaks quickly is against regulatory standards and industry rules. This leads to big penalties and legal action.
Insurance Claims
Inadequate leak detection may impact insurance coverage, claims processing, and premiums as insurers assess risks associated with property damage and liability.
People's Health
Leaks in areas handling dangerous materials can damage public health, such as contact with harmful chemicals, air pollution, and dirty food. This demands proper leak detection actions to protect public health and well-being.
Given below are the problems that our customers face. With the LD1000 Liquid detection system, they were gone.
Limited Space
Small spaces make it difficult for normal leak detection systems that need small solutions like the LD1000.
Finding Leaks Easily
Some areas make it difficult to detect leaks promptly, emphasizing the need for efficient monitoring systems like the LD1000.
Timely Alerting
Delayed water leakage detection can lead to significant damage; hence, systems with immediate and clear alerts, such as the LD1000, are crucial.
Adaptability Issues
Make sure the present cables and detectors are adaptable and connect with different setups easily.
Response Time
Configurable response times are necessary to adapt to varying leak detection requirements, a feature facilitated by the LD1000.
Connectivity Difficulty
Adding new systems into the present monitoring structure can be difficult. However, the LD1000 makes it easy with a Modbus connection.
Exposed Environments
Exposed environments present unique challenges for leak detection, demanding robust and reliable systems like the LD1000.
Maintenance Needs
Regular maintenance is important for good performance. However, the LD1000 makes it less maintenance needs with its good design.
False Alarms
These can be disruptive and costly. Hence, systems like the LD1000 liquid leak sensor with accurate detection mechanisms are preferred.
System Trust
A dependable system is important for leak detection systems to ensure continuous protection against leaks. This is a characteristic feature of the LD1000.
Ease of Installation
Complex installation processes can prolong setup times; however, the LD1000 offers a straightforward installation process, minimizing downtime.
Training Requirements
Training personnel to operate and maintain water leak detection systems can be time-consuming; however, the LD1000's user-friendly interface reduces training needs, improving overall efficiency.