The AQUAPHONE, with its state-of-the-art tech, efficiently detects leaks within water pipe networks. It improves users' leak-locating ability with its superior microphone quality, smart analysis, and clear visual result display.
It is designed for both relocation and precise pinpointing of leaks, the AQUAPHON underground water pipe detector ensures confident excavation and accurate leak identification in any scenario. To pinpoint the exact pipe leak location, it captures vibration waves generated due to leaks and converts them into audible and visual data.
Robust and ergonomic, the receiver boasts an IP67 rating, making it resistant to dust, dirt, and moisture and suitable for use in extreme conditions.
Its symmetrical design accommodates both right-handed and left-handed users, while the TM 200 touch microphone supports continuous underwater operation (IP68).
Key features of this underground water pipeline leak detection system include a clear 5.7-inch display for real-time acoustic intensity and frequency analysis and a durable Li-Ion battery that supports a full day's work. A customized carrying system and wireless ergonomic carrying rod make this unit flexible.
This device can be integrated with the GNSS module for precise geographic documentation of leak location. Users can adjust filter settings with ease, either directly via the touchscreen or manually in detailed increments, ensuring optimal detection conditions.
With the help of WaterCom software, this water leak detector for underground pipes can be connected to laptops using a USB. Hence, users can download data from this device and create detailed maps and reports. Also, this interface can store leak noises for training and future reference.
AQUAPHON's underground pipe leak detection system is equipped with various distinguishing features. Let's have a look at these USPs which make it a professional pipeline leakage detection device.
Electro-Acoustic Technology
The pipe leak locator uses superior microphone quality and measuring technology to enhance the user's ability to detect leaks through intelligent analysis and visual results.
Dual Functionality
Designed for both relocation and pinpointing of leaks, the system ensures accurate detection for confident excavation and reliable outcomes.
Robust Climate Protection
The A 200 receiver is rated IP67, making it impervious to extreme environmental conditions like dirt, dust, and moisture, while the TM 200 touch microphone is fully submersible (IP68).
Ergonomic Design
The pipe leak detection kit features a symmetrical housing that allows operation by both right-handed and left-handed users. It also includes an ergonomically balanced carrying rod.
Clear Visual Feedback
A large 5.7-inch touchscreen display shows acoustic intensity and frequency analysis in real time, aiding in quick assessments and comparisons.
Long Battery Life
This underground leak detector integrated Li-Ion rechargeable battery powers a full day's work, ensuring continuous operation without the need for frequent recharging.
Wireless Communication
Utilizing Sewerin Digital Radio (SDR), the system offers seamless wireless communication between components, reducing interference and enhancing mobility.
Touch Screen Operation
Operated via a sturdy 5.7-inch VGA touchscreen display, the system offers excellent readability and ease of use, even in direct sunlight and while wearing gloves.
Intelligent System Guidance
The leakage detector receiver guides users through applications with clear instructions, making the system accessible to even less experienced operators.
Custom Hearing Protection
Safety features protect the user from sudden loud noises, with automatic muting and reactivation, ensuring comfort and continuous awareness.
Leak Noise Recording
The system includes an audio player for recording and comparing leak noises, allowing for the creation of a noise database useful for onsite analysis and training.
Integrated GNSS Module
An optional GNSS module can pinpoint and document the geographic location of leaks, enhancing the accuracy and utility of maintenance records.
This section will discuss possible repercussions if you do not use an underground pipe leak detector at your facility. Some of the eight points proving disadvantages are as follows:
Increased Water Loss
Without this device, undetected leaks could lead to significant water loss, resulting in higher utility bills and resource depletion, impacting both households and businesses financially.
Higher Repair Costs
Leaks that go undetected for longer periods can cause more severe damage over time. The absence of early pipe leak detection technology would lead to increased repair costs due to extensive damage.
Environmental Degradation
Unmanaged leaks can lead to waterlogging and soil erosion, negatively impacting local ecosystems. Without precise leak detection, such environmental degradation could occur unchecked.
Reduced Operational Efficiency
For water management companies, the inability to quickly and accurately locate leaks would lead to reduced operational efficiency due to increased labor costs and resources to find and fix leaks.
Impact on Public Health
Water pipe leaks can lead to contamination risks, where pollutants enter the water supply. If pipe leakage is not found and repaired quickly, it can compromise water quality and public health.
Infrastructure Damage
Long-standing leaks can weaken the structural integrity of roads and buildings. Without pinpoint accuracy, such infrastructure damages could become more frequent and severe.
Loss of Customer Trust
Water utilities could face reduced customer satisfaction and trust if leaks are not managed efficiently. It can lead to customer dissatisfaction and hence reputation damage.
Increased Emergency Situations
Without effective relocation and pinpointing of leaks, emergencies such as burst pipes could become more frequent, requiring urgent and costly interventions.
Without having an underground water pipe leak detector, our customer faced many difficulties. A few of them are added below.
Detection Problems
Finding leaks in water pipes can be difficult because of their underground place, which needs special tools for proper detection.
Water Loss
Hidden leaks cause a big loss of water, which increases bills and possible property damage.
Property Damage
Leaks can cause too much damage to buildings, such as germs growth and weakening of structures and materials for costly repairs.
Environment Problems
Under the ground, water pipe leaks increase the damage to living things by decreasing soil quality.
Health Problems
Unchecked leaks can cause good conditions for bacteria, which causes health problems for people and impacts indoor air quality.
Work Disturbance
Leaks in workplaces can disturb the production process, causing failure, decreasing productivity, and loss of money.
Safety Concerns
Leaks in gas pipelines cause safety problems, such as fire and blasts, demanding fast detection and repair.
Resource Allocation
Manually inspecting vast networks of pipelines for leaks is labor-intensive and time-consuming.
Difficult To Use
Underground pipes are difficult to find and check water leaks. This becomes more time-consuming.
Data Interpretation
Interpreting data from leak detection tools requires specialized knowledge and training to distinguish between false and actual leaks.
Cost Handling
Balancing the costs of leak detection and possible savings is difficult for companies to save profit.
Legal Factors
Keeping up with legal factors for safety needs good water leak detectors. This saves you from legal troubles.