Leak Detection
Yes
Pipe Locator
Yes
Correlation
Yes
Interface
Software / USB
Display
5.7" TFT
Certifications
FCC, CE, IC, MIC
The SeCorrPhone AC 200 is based on precision acoustic leak detection technology. This one product integrates three essential functions: locating, pinpointing, and correcting leaks. This advanced tool adapts seamlessly to various ambient conditions, allowing users to locate leakage confidently. This underground water leak detection system offers professional-grade results under complex scenarios or standard operation.
Crafted with high-quality piezo microphones and enhanced digital signal processing, the AC 200 excels in its acoustic performance. Its excellent sound quality and noise interference reduction enable the detection of leaks even at low sound intensity or in noisy environments. Users can benefit from tailored filter settings, which are adjustable at the touch of a button or manually, to accentuate leak noises and focus attention without distractions.
The AC 200 underground leak locator's interface is intuitive and logically organized, making it accessible even to less experienced users. The large, clear, 5.7-inch display shows sound intensities both graphically and numerically, alongside historical data and frequency analyses for comprehensive comparison and analysis.
The standout feature of this acoustic leak detection system is its intelligent firmware. It enables the user to automate the measurement process and optimize filter settings. This smart firmware makes this device reliable, accurate, and user-friendly. The large screen of the unit displays data in a format that is simple and easy to interpret and takes follow-up action to confirm the leak location acoustically.
The underground water leak detection system includes an integrated module for precise geographic positioning of leaks for added utility. It pinpoints leak locations by using GNSS technology to link leak noises with exact locations. This feature and the ability to record and replay noises via the integrated audio player. This makes the AC 200 invaluable for current leak assessments and future training or reference purposes.
Users can easily use WaterCom software for measurement, recording, and analysis. This software also facilitates data transfers via USB and edits, annotates, and saves data on interactive maps. WaterCom software enhances its utility by increasing its compressive data handling features. The unique features of AC 200 make it a professional underground leakage detection tool.
SeCorrPhone AC 200 is a professional underground leakage detection system loaded with features. It can find an accurate leak location acoustically with the help of transmitters and microphones.
Professional
It features a clear, logical user interface and advanced piezo microphones optimized for leak detection, ensuring superior sound quality even in noisy environments.
Screen
This underground leak locater is fitted with a large 5.7-inch TFT touchscreen to select settings and see the results regarding graphs and numeric values.
Prelocating Leak
By using the carrying rod with the touch microphone on pipeline fittings, this leak detection system evaluates noise intensity & identifies the likely section of a leak.
Pinpointing
With the help of microphones BM 200 or BM 230 and a carrying rod, it evaluates sound intensity over paved and unpaved surfaces and locates leaks accurately.
Correlation
It uses the principle of correlation which detects leaks by measuring noise at two pipeline fittings, calculating the exact location based on the time lag and pipeline details.
Flexible
This underground water leak detection system combines relocation, pinpointing, and correlation in one device, enabling precise leak detection across various types of pipes.
Intelligent
This acoustic leak detector automates its measurements & optimizes filters for ease of use, providing clear, reliable leak location results on an intuitive display for immediate action.
WaterCom Software
Data from underground leak detection receivers can be easily transferred to a computer, visualized on maps, & annotated for detailed analysis, with options for PDF report generation.
GNSS (Global Navigation Satellite System)
This system can include a GNSS module to record and associate leak noises with precise geographic locations for future reference and effective documentation.
Optimized Filter
It allows easy setting of upper and lower filter limits through clicks on the leak noise graph or manual adjustments in 50 Hz increments for precise control.
Peak Suppressor
Peak suppression in the SeCorrPhon AC 200 clarifies detection by normalizing dominant peaks, enabling easier identification of multiple leaks.
Sound Velocity Measurement
The SeCorrPhon AC 200 measures sound velocity by creating a secondary noise source and comparing two measurements, enabling quick and focused velocity calculations.
There are widespread and significant implications for water management and infrastructure integrity if we do not use supplicated leak detection tools like SeCorrPhon AC 200. Below are a few key impacts of not using this advanced acoustic leak detection technology.
Increased Water Waste
Without the precise underground leak detection capabilities of the SeCorrPhon AC 200, minor leaks could escalate into major leaks, leading to substantial water loss.
Higher Operational Costs
We would potentially incur higher costs due to increased water usage, prolonged leak detection efforts, & escalated repair costs because leaks are not identified accurately.
Infrastructure Damage
Delayed detection increases the risk of significant damage to roadways and building foundations, leading to expensive and extensive infrastructure damage repairs.
Environmental Impact
More prolonged and undetected leaks could result in greater environmental degradation, affecting soil stability and water quality in nearby areas.
Productivity Decreases
Without the integrated functionalities of relocation, pinpointing, and correlation, leak detection efforts become less efficient, requiring more time and resources to identify and resolve issues.
Low Data Accuracy
The absence of the AC 200's advanced filtering and noise analysis features would lead to less accurate leak assessments, resulting in unnecessary excavations & repairs.
Loss of Client Confidence
Businesses and utilities may experience a decline in customer trust if they cannot manage leaks effectively leading to dissatisfaction and potential loss of business.
Regulatory Challenges
Failure to promptly and effectively address leaks may result in violations of regulatory standards, possibly incurring fines due to water conservation laws' violation.
Emergency Response
Without the AC 200 underground water detector's efficient leak localization, emergency response delays could worsen the damage and extend recovery times.
Tech Advancement
Lack of access to advanced tools like the SeCorrPhon AC 200 can hinder professional skill development and slow innovation in leak detection technology.
Check out the blockers in our work before using the SeCorrPhon AC200 underground Leak Detector.
Finding Hidden Leaks
Difficulty in finding leaks hidden in walls, grounds, or machines, causing a lot of damage to the structure.
Manual Checking
Old methods like manual checks make it difficult to find leaks in difficult places. Hence use this detector.
Time-Taking Work
Manual leak detection is very time-consuming as it increases the damage caused by leaks to people.
Wrong Checks
Without good detection tools, proper checking of the leak damage is difficult. Using a leak detector helps.
Environment Impact
Leaks can make a dirty environment like in the case of under-the-ground pipe leaks.
Water and Energy Waste
Leaks cause water and energy wastage, impacting the environment and the future.
Safety Problems
Leaks can increase safety risks to people and workers if not found quickly.
Structure Damage
Water leaks can impact the strength of buildings which decreases the safety of the place.
Machine Failure
Leaks in machines can cause production loss if not found and repaired.
Regulations
Failure to find and repair leaks is taken as not following the industry rules. Facing legal actions.
Protection
Without good leak detectors, important tools and products have a chance of damage.
Loss of Respect
Leaks disturb service and give a bad experience to customers and ratings.